New York, NY

MTA South Ferry Terminal

Scope/Solutions

SGH served as a special consultant to Metropolitan Transit Authority (MTA) Capital Construction to help them with concrete and waterproofing issues at their facilities. As part of our work, SGH investigated widespread cracking and water leakage during construction of the South Ferry Station in Lower Manhattan and its associated running tunnels.

SGH conducted a field investigation and highlights include the following:

  • Documented crack patterns
  • Observed ongoing waterproofing installation and grout injection of cracks
  • Performed nondestructive testing, including ground-penetrating radar, to determine the location and depth of reinforcing steel

We advised MTA about issues with the waterproofing installation and assisted them in evaluating remedial options and waterproofing alternates.

SGH determined the causes of the cracking and helped MTA understand ways to avoid issues contributing to the cracking. Our work also involved developing a model to predict the likelihood of success of the ongoing crack mitigation methods and the service life of the cracked concrete structure.

A large claim developed over the cost of grouting repairs comprising 40,000 lf of cracks and joints. SGH provided expert testimony to the project’s Dispute Resolution Board that was tasked with apportioning responsibility for the costs.

Project Summary

Icon: completion-date

2008

Completion Date
Solutions
Repair & Rehabilitation
Services
Structures | Building Enclosures | Advanced Analysis
Markets
Infrastructure & Transportation
Client(s)
MTA Capital Construction
Specialized Capabilities
Repair & Strengthening | Roofing & Waterproofing | Buried Infrastructure

Key team members

Paul Kelley
Consulting Principal

Additional Projects

Northeast

Brightman Street Bridge

During the six-year rehabilitation of the Brightman Street Bridge, SGH provided investigation and concrete design services and performed testing, analysis, and thermal modeling of mass concrete placements.
Explore
Northeast

601 & 701 Edgewater Drive, Wakefield, MA

The garages at 601 and 701 Edgewater Drive, constructed in the early 2000s, provide three and two levels of parking, respectively. SGH performed condition assessments of the garage structures and subsequently developed a repair program to address deterioration and extend their service life.
Explore