Boston, MA

Logan International Airport, I-90/Route 1A Interchange

Scope/Solutions

The modernization of Logan International Airport included the new I-90/Route 1A Interchange. SGH assisted several contractors that looked for assistance with understanding the complex system of reinforcement, post-tensioning ducts and anchorages, and conduits, as well as with concrete quality at a drilled shaft.

The elevated roadways are constructed of cast-in-place, post-tensioned concrete box girders and supported on individual concrete columns, concrete bents, and concrete abutments. The columns are supported on large diameter drilled shafts. SGH provided construction engineering services, including the following:

  • Preparation of reinforcing bar shop drawings for box girders and straddle bents for direct use in fabrication, reducing delivery time by several weeks
  • Preparation of integrated drawings of box girders and straddle bents showing post-tensioning ducts, anchorages and reinforcement, block outs, reinforcing steel, anchor bolts, earthquake restrainers, drainage systems, and utility conduits to help resolve conflicts between embedded items in advance of construction
  • Evaluation of concrete quality in a major drilled shaft using extracted deep core samples
  • Evaluation of out-of-tolerance drilled shaft reinforcement to show that the drilled shaft was able to carry design loads safely
  • Evaluation and repair design for missing post-tensioning bars in one of the straddle bents

Project Summary

Icon: completion-date

2007

Completion Date
Solutions
New Construction
Services
Structures
Markets
Infrastructure & Transportation
Client(s)
Barletta Heavy Division
Specialized Capabilities
Temporary Construction

Key team members

William Konicki
Senior Principal
Stan Zagajeski
Consulting Technical Director

Additional Projects

Northeast

Harvard Towers Parking Garage

Constructed around 1962, Harvard Towers includes a two-level, below-grade parking garage below the ground-level plaza. SGH investigated the cause of deterioration and designed a rehabilitation program for the garage.
Explore
Northeast

Providence Place Mall Parking Garages

The garages exhibited chronic, premature cracking and spalling of the concrete around precast double-tee flange-to-flange connections as well as other common parking structure deterioration and distress.  SGH assessed the condition of the garages and designed remedial work.